Elettra-Sincrotrone Trieste S.C.p.A. website uses session cookies which are required for users to navigate appropriately and safely. Session cookies created by the Elettra-Sincrotrone Trieste S.C.p.A. website navigation do not affect users' privacy during their browsing experience on our website, as they do not entail processing their personal identification data. Session cookies are not permanently stored and indeed are cancelled when the connection to the Elettra-Sincrotrone Trieste S.C.p.A. website is terminated.
More info
OK

Control Software

Beamline Control System (BCS)




In brief

The BCS provides a webpage interface which can be accessed from all computers connected to the Elettra network at http://adam.elettra.eu/projects/blcs/beamwatch/061/msb_main.bwh. It shows the current electron beam parameters, layout of the beamline, status of the valves (green = closed, red = open) and pressures in the vacuum chambers.

Moreover, opening the webpage on the MSB-MASTER computer permitis to operate the 10 electropneumatic valves labelled with numbers in the screenshot above.

The most useful information and valve operations are mirrored into the Kleopatra software.

For instructions see Opening and closing the beamline.

If the webpage does not open proceed with Troubleshooting - BCS communication problem.

Further details

The webpage automatically refreshes every 40 seconds. If you need to refresh the information immediately user the FORCE REFRESH link or the Reload button of your web browser.

 Logging system contains changes in every parameter or status.

Color coding of the beamline elements is:
  • green: normal operation
  • yellow: warning but still safe
  • red: failure or risk
  • blue: communication error, and therefore status unknown
The pressures are read from the gauge controllers in the front-end and beamline racks. Bear in mind that the displayed gauge in the analysis chamber is the coarse cold-cathode and NOT the precise ionization gauge that we read in the end-station rack, so the reading might differ.

Other information that is available on the webpage:
  • status of the water cooling circuits of the prefocusing mirror, entrance slit and monochromator (plain mirror + plane grating) by clicking on the Water system link): normal flux, not much flux or no flux
  • status of the ion pumps by clicking on the corresponding vacuum chambers as read from the corresponding power supplies in the front-end and 2 beamline racks.
Any parameter available on the BCS webpage can be logged and graphically displayed using the Pressure Watcher software (e.g. pressure in the monochromator of the analysis chamber).