Manuals

Beamline in General

alt BACH beamline in brief
Safety and General Rules
Beamline Control System (BCS)

EndstationA Instruments

alt

Scienta3000
Comix
Channeltron
Keithley
X-Ray Source (Igor)
X-Ray Source
MCP-Fluorescence
Sample Manipulation and carriers
Laser (Sincrotrone Trieste)
old: XPS (VSW)
Off Line Tools
INVENTARIO



EnstationA Procedures

alt

Sample Transfer
Data Analysis

XPS Data Analyis with KolXPD
ResPES spectra processing
Manip. Positions
Annealing
Cooling
Sputtering
Sample cleaning
LEED

Evaporation and sample preparation
XAS
MCP-Fluoresce Yield
TR XAS Data acquisition and data loading
ARPES and SX ARPES
XPS-some useful parameters
PID temperature controller
Work Function measurements
 

Beamline Procedures (How to)

alt

Select and optimize the energy (monochromator, undulator optimization)
Select a different grating of the mono

Select the ZERO ORDER of the mono
Switch the Undulators
OpenClose BLValves
select the EnergyResolution
Switch the Branchline
Adjust the prevert pitch (micrometer along the beam)
Align the Double Slits
Restart the BCS: Manual and this doc
Laser 
MIRA Operating Procedure and Synchronization (not for users)
Laser lock

Laser set-up

Small beam and Ref positions
C
hange rotation speed Pfeiffer
E
dwards Mini Turbo Operation
C
ontrolled Powercut (spegnimento Privilegiata)


Hardware Troubleshooting and pdf Instrument Manuals

alt

The Shutter is closed and it cannot be opened
The FE is open, but there is no signal
Io or Is are very noisy.
It is not possible to raise the energy above 0.6 keV in the Sputtering Power Controller.

Sputtering gun filament replacement and cleaning
Recover from a powercut
Heideneim controller switched off (power failure).

Seiko seiki STP300/400 controller needs to be tuned (power failure)      
National Instruments BNC-2120   
National Instruments PCI 6035 board
Entrance/Exit Slit in End Switch
VACO controller cards
RGA mass spectra are noisy

Software Troubleshooting

alt

The Monochromator does not move and does not read correctly
The Energy or Motor scan are slow and I0 reads 0 every 2 or 3 points
Edit Energy Regions in ScanEnergy.VI
Mono PC to be rebooted (NEW)
BCS not working
SES blocked during NEXAFS, ResPES scan
Restart Scienta R3000

PC Labview in Edit Mode PC
Username and Password
Overwrite or restore?
An Error Message pops up
The Acquisition PC or LABVIEW has to be restarted
Igor Pro procedures
How to Disable/Enable Backup and Sync applications