XRD1 Specifications
Page 2 of 6
X-rays at sample
Energy range |
4-21.5 keV |
Photon Flux |
1012-1013 ph/sec |
Beam Size at sample |
0.7 x 0.2 mm2 FWHM (unconstricted; precision slits for beam shaping) |
Angular divergence |
2.3 mrad x 0.3 mrad FWHM |
Source
Type |
Insertion Device: NdBFe Multipole Wiggler (Hybrid linear) |
Section |
5.2 |
Gap |
22 mm |
Poles |
57 |
Period |
140 mm |
N. of periods |
3 x 9.5 |
B0 |
1.607 T |
Ec |
4.27 keV |
K |
21 |
Source Size FWHM |
2.0 x 0.37mm |
Power (9mrad) |
8.2 kW |
Optics
Collimating Mirror
|
Cilindrical Mirror with 50 nm Pt-coating
Radius (calculated) = 14.8 km
Distance from source = 21873 mm
Incidence angle = 3 mrad
|
Monochromator
|
Fixed exit Double Crystal Si111 with LN2 cloosed loop cooling
Distance from source = 24059 mm
Energy range = 4-21 keV
Energy resolution = 10-4 for routine experiments and MAD experiments
Fine tuning with piezo actuator; feedback from 4-quadrant ion chamber |
Focusing mirror |
Toridal Mirros with 50 nm Pt-coating
Tangential radius = 9.31 km
Sagittal radius = 55.27 mm
Distance from source = 28018 mm
Incidence angle = 3 mrad |
|
|